  • Brand:: Unipulse
  • Model:: F701-C

Unipulse F701-C weighing controller with accumulation function

F701-C is a general-purpose weighing controller that is compatible with all weighing systems. This is a practical device excellent in cost effectiveness, which is equipped with the final discharge function allowing high-accuracy feeding and discharging weighing control and the weighing sequence function essential to hopper and packing scales. 
Installable is the interface that can be connected to PLCs or various peripherals such as BCD output, RS-232C and CC-Link.

選型F701-C.jpg

ANALOG SECTION
Excitation voltage10V DC ±5%, Output current; within 120mA (Up to 4 loadcells at 350Ω are parallel-connectable)
Zero adjustment range0 - 2mV/V
Rough adjustment: Digitally controlled via rough adjustment circuit
Fine adjustment: Auto adjusting method via digital processing
Gain adjustment range0.3 - 3.2mV/V
Rough adjustment: Digitally controlled via rough adjustment circuit
Fine adjustment: Auto adjusting method via digital processing
Min. input sensitivity0.3μV / count
AccuracyNon-linearity: within 0.01% FS 
Zero drift: within 0.2μV/°C RTI
Gain drift: within 15 ppm/°C
Analog filterBessel low-pass filter (-12dB/oct.), Selectable from 2, 4, 6, 8 Hz
A/D converterSpeed: 200 times/sec
Resolution: 24 bit (binary)
 
SETTING SECTION
Setting items- High limit, Low limit, near zero, SP1, SP2, Compensation, over, under, final
- Comparison inhibit time, judging time, complete output time, adjust feeding time, auto zero times, judging times. Auto free fall compensation regulation, analog filter, tare weight
- Weighing function 1, weighing function 2, weighing function 3, sequence mode, function key inhibit, digital filter, motion detect, zero tracking period, zero tracking range
- Balance weight value, capacity, min. scale division, net over, gross over, DZ regulation value, function selection, gravitation acceleration (area number input), gravitation acceleration (acceleration input)
- D/A output mode, D/A zero output weight, D/A full scale, RS-485 I/F, ID number, RS-232C I/F, external function selection, setting value LOCK, restriction on the tare subtraction function
- Input selection, output selection, CC-Link I/F Occupied station & Transmission speed, CC-Link I/F Station No.
- Average weight, maximum weight, minimum weight, population standard deviation, sample standard deviation, number of data (n), latest accumulation date, Maximum-minimum (R), option substrate
- Span calibration, equivalent input calibration, password input, zero calibration
 
INPUT/OUTPUT SECTION
External output signalTransistor’s open collector output (Emitter = COM terminal); Output is LO when transistor is ON. Near zero, SP1, SP2, SP3, under, over, Low limit, high limit, stable, weight alarm or error, go or complete, run or accumulation error
External input signal

ON when shorted to COM terminal by contact (relay, switch) or non contact (TTL-level transistor or open collector output) G/N, digital zero, tare subtraction ON, tare subtraction OFF, hold*, judge*, feed / discharge, start*, stop*, accumulation command*, accumulation clear*

*Signals for selection. Up to 4 can be selected.

Interface
  • SIF:

  • 2-wire type serial interface (standard); Interface to link with Unipulse printer or external display

  •  

  • 232:

  • RS-232C communication interface (standard): Write (change) / read weight data, various statuses and setting values by commands from a host computer

  •  

  • BCO:

  • BCD parallel data output interface (Optional): Parallel interface to transmit weight data to various peripherals

  •  

  • 485:

  • RS-485 communication interface (Optional): Allows longer-distance communication than RS-232C. ID numbers are set, and multiple units of F701-C are parallel-connectable.

  •  

  • DAC:

  • D/A converter interface (Optional); Interface to convert weight data to current signal and output it.

  •  

  • CCL:

  • CC-Link interface (Optional); Links directly to PLC.

 
DISPLAY SECTION
Display unitNumerical display (7 digits) with a character height of 10.4 mm by fluorescent display tube, Sub-display; character height 4.0 mm
Display value5 digits, Sign; Minus sign displayed on most significant digit
UnitSelectable from t, kg, g, N, lb, none
Status displaySP1, SP2, SP3, NEAR ZERO, HOLD, ZERO ALARM, STAB, TARE, NET, ZERO, BATTERY CONDITIONS
 
GENERAL SPECIFICATIONS
Power supply voltage100 - 240V AC (+10% - 15%) (Free power supply 50/60 Hz)
Power consumptionApprox. 15VA
Operating conditionsTemperature: Working temperature range -10 - +40°C; Storage temperature range -20 - +85°C
Humidity: 85% RH or less (non-condensing)
External dimensions144 (W) x 72 (H) x 160 (D) [mm] (protruding parts not included)
WeightApprox. 1.0 g
 
OPTION
BCOBCD parallel data output interface
485RS-485 communication interface
DACD/A converter interface
CCLCC-Link interface
Number of mountable options1
 
ACCESSORIES
AC input cord (nominal rating: 125V) 3m1
Mini-driver1
FCN series I/O connector (with cover)1
Jumper cable2
Operation Manual1
BCD output connector (when BCD output option is installed)1
RS-485 connector (when RS-485 option is installed)1
D/A converter connector (when D/A converter option is installed)1
CC-Link connector (when CC-Link option is installed)1
  
Drum Filling Machine

Option

ModelDescription
BCOBCD parallel data output interface
485RS-485 communication interface
DACD/A converter interface
CCLCC-Link interface
  
Drum Filling Machine

Optional accessories

ModelDescription
CAAC2P-B3AC Supply cord 3m
CAAC3P-CEE7/7-B2AC Supply cord (Voltage resistance:250V)2m
CN34D-Sub 9p connector for RS-232
CN50FCN series I/O connector (with cover)
CN55FCN series I/O connector (with diagonal cover)
CN70D/A converter connector
CN71RS-485?CC-Link connector
CN80Analog I/O connector terminal
F720 mounting panelMounting panel for F252 / F280 to F701-C conversion
LB01-XHLithium battery (with XH connector)


CONTACT US

Skype: fayfaywang1027

QQ: 429682794

Whatsapp: 008618016442021

E-mail: glzoncn@163.com

https://glzon.en.alibaba.com/

cel: +0086 18016442021

主站蜘蛛池模板: 亚洲国产一区二区三区a毛片 | 手机在线成人精品视频网 | 午夜在线观看网站 | 91视频污版 | 巨大乳hdbbw| 四虎永久在线精品国产 | 日本一区二区免费在线观看 | 91亚洲人成手机在线观看 | 好吊色综合网天天高清 | 免费一级毛片在线播放 | 亚洲欧美一二三区 | 999久久66久6只有精品 | 免费视频成人国产精品网站 | 中文字幕日韩一区二区三区不卡 | 亚洲国产日韩欧美综合久久 | 欧美日韩在线精品一区二区三区 | 亚洲精品久荜中文字幕 | 黑人极品videos精品欧美裸 | 国产免费a v吧在线观看不卡 | 亚洲精品天堂一区二区三区 | 日本大胆一区免费视频 | 欧美孕妇乱大交xxxx | www.天天操 | 欧美综合在线视频 | 成人不卡在线 | 24小时日本免费观看视频www | 日韩欧美在线不卡 | 精品视频在线一区 | 日本一级毛片免费播放 | 久久频精品99香蕉国产 | 2021久久精品国产99国产 | 91精品自在拍精选久久 | 大奶影视 | 欧美日韩视频一区二区 | 男人和女人做免费做爽爽视频 | 天天摸天天操 | 91精品综合国产在线观看 | 日本福利视频在线观看 | 日韩一区二区三区四区五区 | 亚洲成人第一页 | 91人人爱 |